The IP Code (or International Protection Rating[1], sometimes also interpreted as Ingress Protection Rating) consists of the letters IP followed by two digits and an optional letter. As defined in international standard IEC 60529, it classifies the degrees of protection provided against the intrusion of solid objects (including body parts like hands and fingers), dust, accidental contact, and water in electrical enclosures.[2] The standard aims to provide users more detailed information than vague marketing terms such as "waterproof".
Also known as index protection,
The digits ('characteristic numerals') indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X.
For example, an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. IP22 or IP2X are typical minimum requirements for the design of electrical accessories for indoor use.
Contents[hide] |
The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects.
Level | Object size protected against | Effective against |
---|---|---|
0 | — | No protection against contact and ingress of objects |
1 | >50 mm | Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part |
2 | >12.5 mm |
Fingers or similar objects |
3 | >2.5 mm |
Tools, thick wires, etc. |
4 | >1 mm |
Most wires, screws, etc. |
5 | dust protected |
Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact |
6 | dust tight |
No ingress of dust; complete protection against contact |
Protection of the equipment inside the enclosure against harmful ingress of water.
Level | Protected against | Details |
---|---|---|
0 | not protected | — |
1 | dripping water |
Dripping water (vertically falling drops) shall have no harmful effect. |
2 | dripping water when tilted up to 15° |
Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15° from its normal position. |
3 | spraying water |
Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect. |
4 | splashing water |
Water splashing against the enclosure from any direction shall have no harmful effect. |
5 | water jets |
Water projected by a nozzle against enclosure from any direction shall have no harmful effects. |
6 | powerful water jets |
Water projected in powerful jets against the enclosure from any direction shall have no harmful effects. |
7 | immersion up to 1 m |
Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion). |
8 | immersion beyond 1 m |
The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. |
The standard defines additional letters that can be appended to classify only the level of protection against access to hazardous parts by persons:
Level | Protected against access to hazardous parts with |
---|---|
A | back of hand |
B | finger |
C | tool |
D | wire |
Further letters can be appended to provide additional information related to the protection of the device:
Letter | Meaning |
---|---|
H | high voltage device |
M | device moving during water test |
S | device standing still during water test |
W | weather conditions |
An additional number has sometimes been used to specify the resistance of equipment to mechanical impact. This has now been superseded by the separate IK number specified in EN 50102.
Although dropped from the 3rd edition of IEC 60529 onwards, and not present in the EN version, older enclosure specifications will sometimes be seen with an optional third IP digit denoting impact resistance. Newer products are likely to be given an IK rating instead. However there is not an exact correspondance of values between the old and new standards.
OLD IP Level | Impact energy | Equivalent drop mass and height |
---|---|---|
0 | — | — |
1 | 0.225 J |
150 g dropped from 15 cm |
2 | 0.375 J |
250 g dropped from 15 cm |
3 | 0.5 J |
250 g dropped from 20 cm |
5 | 2 J |
500 g dropped from 40 cm |
7 | 6 J |
1.5 kg dropped from 40 cm |
9 | 20.0 J |
5.0 kg dropped from 40 cm |
IK number |
Impact energy (joules) |
Equivalent impact |
---|---|---|
00 | unprotected | no test |
01 | 0.150 | drop of 200 gram object from 7.5 cm height |
02 | 0.200 | drop of 200 gram object from 10 cm height |
03 | 0.350 | drop of 200 gram object from 17.5 cm height |
04 | 0.500 | drop of 200 gram object from 25 cm height |
05 | 0.700 | drop of 200 gram object from 35 cm height |
06 | 1.00 | drop of 500 gram object from 20 cm height |
07 | 2.00 | drop of 500 gram object from 40 cm height |
08 | 5.00 | drop of 1.7 kg object from 29.5 cm height |
09 | 10.0 | drop of 5 kg object from 20 cm height |
10 | 20.0 | drop of 5 kg object from 40 cm height |
German standard DIN 40050-9 extends the IEC 60529 rating system described above with an IP69K rating for high-pressure, high-temperature wash-down applications.[3] Such enclosures must not only be dust tight (IP6X), but also able to withstand high-pressure and steam cleaning. The test specifies a spray nozzle that is fed with 80°C water at 8–10 MPa (80–100 bar) and a flow rate of 14–16 L/min. The nozzle is held 10–15 cm from the tested device at angles of 0°, 30°, 60° and 90° for 30 s each. The test device sits on a turntable that rotates once every 12 s (5 rpm).
The IP69K test specification was initially developed for road vehicles, especially those that need regular intensive cleaning (dump trucks, cement mixers, etc.), but also finds use in other areas (e.g., food industry).
NEMA enclosure ratings have equivalent IP ingress protection ratings as follows. NEMA enclosure standards also dictate other product features not addressed by IP codes (such as submersibility, operation under icing conditions, and others). [4]
NEMA Enclosure | IP Code |
---|---|
4, 4X | IP66 |
12 | IP52 |
13 | IP54 |
North American enclosure rating systems are defined in NEMA 250, UL 50, UL 508, and CSA C22.2 No. 94.
North American ingress-protection rating systems are defined in NEMA 250, UL 50, UL 508, and CSA C22.2 No. 94.
NEMA STARTER (0) | 2009.10.16 |
---|---|
외함에 관한 NEMA의 IP 등급 (0) | 2009.09.14 |
외함의 보호등급 (IP code) (0) | 2009.09.14 |
CLOUDMARK 그리는 법 (0) | 2009.08.31 |
SI 단위와 공학단위의 차이점 (0) | 2009.08.17 |
댓글 영역