Converting from NEMA enclosure classifications to IEC enclosure classifications
src = http://www.engineeringtoolbox.com/nema-enclosures-d_919.html
NEMA enclosure classifications are developed by NEMA and used in the U.S./American market.
Ingress Protection - IP - ratings are developed by the European Committee for Electro Technical Standardization (CENELEC) (described IEC/EN 60529), and specifies the environmental protection and enclosure provided.
The table below can be used to convert from NEMA Enclosure Types to IEC Enclosure Types:
NEMA Enclosure Types | IEC Enclosure Classification Designation | ||
1 | General Purpose - Indoor | IP10 | Protected against solid objects up to 50mm, e.g. accidental touch by hands. |
2 | Drip-Proof - Indoor | IP11 | Protected against solid objects up to 50mm, e.g. accidental touch by hands. Protection against vertically falling drops of water e.g. condensation. |
3 | Dusttight, Raintight, Sleettight - Outdoor | IP54 | Protected against dust limited ingress (no harmful deposit). Protection against water sprayed from all directions, limited ingress permitted. |
3R | Raintight, Sleet Resistant- Outdoor | IP14 | Protected against solid objects up to 50mm, e.g. accidental touch by hands. Protection against water sprayed from all directions, limited ingress permitted. |
3S | Dusttight, Raintight, Sleettight- Outdoor | IP54 | Protected against dust limited ingress (no harmful deposit). Protection against water sprayed from all directions, limited ingress permitted. |
4 | Watertight, Dusttight, Sleet Resistant-Indoor & Outdoor | IP56 | Protected against dust limited ingress (no harmful deposit). |
4X | Watertight, Dusttight, Corrosion-Resistant- Indoor & Outdoor | IP56 | Protected against dust limited ingress (no harmful deposit). |
5 | Dusttight, Drip-Proof--Indoor | IP52 | Protected against dust limited ingress (no harmful deposit). Protection against direct sprays of water up to 15o from the vertical. |
6 | Occasionally Submersible, Watertight, Sleet Resistant- Indoor & Outdoor | IP67 | Totally protected against dust. Protected against the effect of immersion between 15cm and 1m. |
6P | Watertight, Sleet Resistant- Prolonged Submersion- Indoor & Outdoor | IP67 | Totally protected against dust. Protected against the effect of immersion between 15cm and 1m. |
12 | Dusttight and Driptight- Indoor | IP52 | Protected against dust limited ingress (no harmful deposit). Protection against direct sprays of water up to 15o from the vertical. |
12K | Dusttight and Driptight, with Knockouts- Indoor | IP52 | Protected against dust limited ingress (no harmful deposit). Protection against direct sprays of water up to 15o from the vertical. |
13 | Oiltight and Dusttight- Indoor | IP54 | Protected against dust limited ingress (no harmful deposit). Protection against water sprayed from all directions, limited ingress permitted. |
Note! NEMA standards meet or exceed IEC standards. The conversion does not work in the opposite direction.